The Damper Sits at the Bottom of the Flue and Takes Its Weather
Ask About Chimney Damper Repair
Name the street and what the chimney serves. Our reply sets out the visit and any published price.
What the Job Includes
The throat damper takes direct heat from every fire, and in time the plate warps, the hinge rusts or the handle linkage snaps. We free and adjust a usable plate, swap a damaged one where the frame allows, or fit a top-mounted damper that seals the flue at the cap and works from a cable in the firebox. If an insert or liner is planned, the damper is handled inside that job.
What Lands on a Damper Over the Years
In most older Maywood fireplaces the damper is a cast iron plate in a frame set into the throat, right where the firebox narrows into the smoke chamber. It sits at the bottom of the flue, which means everything that comes down the flue lands on it. Rain from an uncapped chimney sits on the plate and in the frame after every storm, and over years the hinge pins rust solid and the plate warps. Soot and creosote build up on the edges so the plate no longer seats. Pieces of broken tile and mortar from higher up drop onto the plate and jam it. Nests and leaves fall into the smoke chamber and lie on top. So when a damper sticks, the question for us is not only how to free it, but what is coming down the flue to cause it. A light past the damper, and the camera when the signs point higher, shows us whether the flue is shedding tile or open to the rain.
There are a few repairs we make to the throat damper itself. A seized pivot can often be freed and the plate cleaned so it closes properly. Snapped linkage parts are swapped for new ones. Holes eaten through the iron, or a casting split across one corner, are past saving, and replacing the whole throat damper means cutting out the old frame and setting a new one in the masonry, which is a bigger job in a tight space. Often a better choice is a damper at the top of the flue. This spring-loaded lid bolts above the highest tile or liner, and a lever by the fireplace opening, linked through a long steel line, raises it or pulls it shut. It seals tighter than a cast iron plate, and the old throat damper is left fixed open or removed.
Dampers, Liners and Gas Logs
Two other jobs change what the damper has to do. Relining for an insert or a stove means the stainless has to travel through the throat, so the old iron plate is taken out or pinned back permanently. The liner then has its own cap, and a damper is no longer part of the setup. When a vented gas log set goes in, the damper has to be locked partly or fully open so the exhaust always has a way out, and a top-sealing damper is a popular pair for that, since it can be closed when the logs are off and stop warm room air drifting out. If either job is coming soon, it makes sense to plan the damper fix with it rather than paying to repair a throat damper that is about to be bypassed. We say so when that is the case.
Damper work has no list price on this site. Freeing and cleaning a throat damper is a small job; replacing one in the masonry is larger; a top-sealing damper is priced from the size and shape of the flue top. Each is written up after we have looked at the damper and up the flue, with any cap or crown work kept on its own line. If the damper problem is part of a sale and has turned up on a buyer's report, the up to code page covers how we write that scope. For owners in Maywood, Downey and South El Monte, tell us on the contact page whether the damper will not open, will not close, or moves but does not seal, and whether the fireplace burns wood or gas.
How Hayward Chimney Pros Works
Footage First
Each recommendation points to a still from the flue
Sized to Fit
Liners and caps matched to the appliance below
Itemized Scope
Every line priced before any work begins
Filmed Again
After stills taken at the same depths
Where we offer chimney damper repair
Focus cities link to a local page on this job; the others link to their city overview. Search by name below.
Nothing on the list under that spelling. Clear the box to see every city.
Other Chimney Services
Chimney Sweep
Creosote glaze and loose soot cleared from tile or steel walls, then a camera confirms the flue is bare before we pack up.
Open →Chimney Inspection
NFPA 211 inspections read from the flue outward, with tile joints, offsets and the crown recorded on camera.
Open →Chimney Repair
Cracked tiles, open joints and failed mortar fixed in an order set by what the inspection footage found, top first.
Open →Fireplace Inspection
The room end of the system checked: firebox brick, damper seat, hearth extension and the throat where smoke enters the flue.
Open →Fireplace Repair
Spalled firebrick, a cracked rear panel, a warped damper or a gap at the throat repaired so smoke heads up the flue.
Open →Chimney Level 2 Inspection
A camera pulled through every foot of the flue, with attic and roof passages checked and the footage kept on file.
Open →Chimney Cap Installation
A cap sized to the tile or liner outlet, with a spark screen and fixings that suit the crown it sits on.
Open →Chimney Flashing Repair
Leaks along the roof joint found by water test, then step and counter metal renewed so the attic stays dry.
Open →Chimney Masonry Repair
Spalled brick, sandy joints and loose courses repaired on the outside of the stack, matched in hardness to the old work.
Open →Chimney Rebuilds
A chimney too cracked or loose to patch taken down and rebuilt, with a new flue sized to whatever it will serve.
Open →Fireplace Cleaning
Ash, soot and tar residue cleared from the firebox, doors and smoke shelf so the opening looks and draws as it should.
Open →Gas Fireplace Cleaning
Burner ports, pilot hood and glass cleaned on a gas unit, with the vent run checked for nests, rust and loose joints.
Open →Gas Fireplace Repair
Ignition faults, weak flames and shutdowns on gas units traced with a meter, then fixed with the listed replacement part.
Open →Fireplace Remodel
A refaced or rebuilt fireplace planned from the flue up, so the new look sits on a firebox and liner that work.
Open →Fireplace Inserts
Wood or gas inserts fitted with a stainless liner run to the top, sized by flue area so the draft matches the appliance.
Open →Pellet Stove Repair
A pellet stove that jams, fails to light or shuts itself off, traced part by part, with its exhaust pipe cleared of fly ash.
Open →Wood Stove Repair
Baffles, firebrick, door seals and the connector pipe on a wood stove repaired, with the flue checked for tar above the collar.
Open →Gas Logs
A gas log set placed where the wood fire used to burn, with the flue kept clear for exhaust from a vented burner.
Open →Chimney Seismic Retrofit
Unreinforced brick chimneys braced, banded or rebuilt lighter above the roof, after a camera check of the flue inside.
Open →Chimney Crown Repair
Cracks across the chimney top sealed or the top recast, so rain stops getting to the flue tile from above.
Open →Dryer Vent Cleaning
Lint packed in the dryer duct cleared from end to end, with the run checked for crushed sections and a stuck outside flap.
Open →Chimney Liner Installation
Stainless liners chosen by diameter and alloy for the appliance below, run in one length to a sealed top.
Open →Chimney Leak Repair
Damp walls, rusty dampers and drips in the firebox followed up the chimney to where the water enters, then stopped there.
Open →Chimney Waterproofing
A breathable repellent on repaired chimney brick, so the masonry sheds rain and still dries out between storms.
Open →Chimney Chase Cover
Rusted or sagging metal tops on prefab chimneys replaced with a custom stainless top that pitches water away from the pipe.
Open →