The Bottom of the Flue Starts at Your Firebox

Ask About Fireplace Inspection

What the Job Includes

This visit is about the opening and the first couple of feet above it, where the fire does its hardest work. We check firebrick and joints, the damper plate and seat, the throat and smoke shelf, the hearth extension and the gap to trim and mantel. On factory-built units we read the listing label, which decides which liners, doors and inserts that box may take later.

Firebrick faces and joints tapped and read
Damper seat and plate checked for warping
Throat and smoke shelf lit and photographed
Hearth extension and trim gaps measured
Factory label read for approved add-ons

Where the Fireplace Hands Off to the Flue

People tend to think of the fireplace and the chimney as two things. From the inside they are one passage that changes shape. The firebox is wide and open, the throat above it narrows to the damper, the smoke chamber tapers like a funnel, and the flue carries on as a straight tube to the top. Every one of those changes is a place where something can go wrong. In a masonry fireplace we check the firebrick and the mortar between it, the cast iron or steel damper frame, and the inside of the smoke chamber, which in many older Maywood houses was left as rough stepped brick instead of a smooth parged surface. Stepped brick catches creosote, and gaps in it can let heat through to the framing. Most important to us is the first flue tile: whether it sits square on the smoke chamber, whether the joint there is sealed, and whether it has cracked from years of being the hottest part of the flue.

Factory-built fireplaces are a different animal. Plenty of Downey tract homes and Los Angeles condos instead carry a prefab: a steel box and a double or triple wall pipe that a manufacturer tested together and sold as one listed assembly. On those we read the label plate inside the opening, since it names the model and what the unit allows, and we look at the refractory panels, the screen, the damper and the first section of pipe for warping, rust and gaps at the joints. A cracked panel or a pipe joint that has separated is a fire risk on a metal unit in a way it is not on brick, because there is so little between the fire and the wood around it. If the house has a gas line to the fireplace, we note the valve and the log set. A Level 1 inspection is $52 and covers the fireplace and every other reachable part of the chimney.

When the Fireplace Check Needs to Go Higher

Some findings at the firebox are really about the flue. Smoke that rolls out under the opening on a calm night can mean a damper that does not open fully, a smoke chamber packed with debris, or a flue that is too small for the size of the opening. Brown streaks on the brick face above the opening point to the same draft problem. Flakes of glaze in the firebox after a fire, or a crumbled piece of clay on the smoke shelf, tell us the tile higher up is breaking down. In each of those cases we explain why the fireplace is acting the way it is and whether the flue needs a camera to confirm it. That camera work is a Level 2 inspection at $370, and on a house being bought or sold it is usually the right level from the start, since the buyer needs to know about the parts no one can see.

If you are planning changes, an inspection is the right first visit. An insert, a gas log set or a new surround all depend on the condition of the firebox and on what sits above it. An insert needs a firebox big enough to take it and a flue path for its liner. A log set needs a working damper and a clear flue. A new stone or tile face needs to sit at a safe distance from the opening, which we measure while we are there. For property managers with several units in a building, each fireplace is looked at on its own, and the findings are listed by unit so repairs can be planned across the building. To book, use the contact page and tell us whether the fireplace is brick or metal, what it burns and what you are thinking of changing.

How Hayward Chimney Pros Works

Footage First

Each recommendation points to a still from the flue

Sized to Fit

Liners and caps matched to the appliance below

Itemized Scope

Every line priced before any work begins

Filmed Again

After stills taken at the same depths

Other Chimney Services

Chimney Sweep

Creosote glaze and loose soot cleared from tile or steel walls, then a camera confirms the flue is bare before we pack up.

Open →

Chimney Inspection

NFPA 211 inspections read from the flue outward, with tile joints, offsets and the crown recorded on camera.

Open →

Chimney Repair

Cracked tiles, open joints and failed mortar fixed in an order set by what the inspection footage found, top first.

Open →

Fireplace Repair

Spalled firebrick, a cracked rear panel, a warped damper or a gap at the throat repaired so smoke heads up the flue.

Open →

Chimney Level 2 Inspection

A camera pulled through every foot of the flue, with attic and roof passages checked and the footage kept on file.

Open →

Chimney Cap Installation

A cap sized to the tile or liner outlet, with a spark screen and fixings that suit the crown it sits on.

Open →

Chimney Flashing Repair

Leaks along the roof joint found by water test, then step and counter metal renewed so the attic stays dry.

Open →

Chimney Masonry Repair

Spalled brick, sandy joints and loose courses repaired on the outside of the stack, matched in hardness to the old work.

Open →

Chimney Rebuilds

A chimney too cracked or loose to patch taken down and rebuilt, with a new flue sized to whatever it will serve.

Open →

Fireplace Cleaning

Ash, soot and tar residue cleared from the firebox, doors and smoke shelf so the opening looks and draws as it should.

Open →

Gas Fireplace Cleaning

Burner ports, pilot hood and glass cleaned on a gas unit, with the vent run checked for nests, rust and loose joints.

Open →

Gas Fireplace Repair

Ignition faults, weak flames and shutdowns on gas units traced with a meter, then fixed with the listed replacement part.

Open →

Fireplace Remodel

A refaced or rebuilt fireplace planned from the flue up, so the new look sits on a firebox and liner that work.

Open →

Fireplace Inserts

Wood or gas inserts fitted with a stainless liner run to the top, sized by flue area so the draft matches the appliance.

Open →

Pellet Stove Repair

A pellet stove that jams, fails to light or shuts itself off, traced part by part, with its exhaust pipe cleared of fly ash.

Open →

Wood Stove Repair

Baffles, firebrick, door seals and the connector pipe on a wood stove repaired, with the flue checked for tar above the collar.

Open →

Gas Logs

A gas log set placed where the wood fire used to burn, with the flue kept clear for exhaust from a vented burner.

Open →

Chimney Seismic Retrofit

Unreinforced brick chimneys braced, banded or rebuilt lighter above the roof, after a camera check of the flue inside.

Open →

Chimney Crown Repair

Cracks across the chimney top sealed or the top recast, so rain stops getting to the flue tile from above.

Open →

Dryer Vent Cleaning

Lint packed in the dryer duct cleared from end to end, with the run checked for crushed sections and a stuck outside flap.

Open →

Chimney Liner Installation

Stainless liners chosen by diameter and alloy for the appliance below, run in one length to a sealed top.

Open →

Chimney Leak Repair

Damp walls, rusty dampers and drips in the firebox followed up the chimney to where the water enters, then stopped there.

Open →

Chimney Waterproofing

A breathable repellent on repaired chimney brick, so the masonry sheds rain and still dries out between storms.

Open →

Chimney Damper Repair

A damper that sticks, rattles or shows daylight repaired at the throat, or replaced with a sealing top damper.

Open →

Chimney Chase Cover

Rusted or sagging metal tops on prefab chimneys replaced with a custom stainless top that pitches water away from the pipe.

Open →
Request a Visit